Product Specifications


 





 




Product Description




































 



Water Cooled Chiller



Water Cooled Chiller, also known as packaged water cooled chiller or water cooling chiller, is an efficient and reliable industrial cooling equipment. It dissipates heat through the circulation of cooling water and requires connection to a cooling tower or cooling device to exhaust the generated heat. Compared to air cooled chillers, water cooled chillers typically offer higher cooling efficiency and lower noise levels. Additionally, they provide flexible capacity and specification options to meet different process requirements. The refrigeration range of water cooled chillers is extensive, ranging from 2967 Kcal/h to 139664 Kcal/h, and they can provide chilled water with a temperature range of 3°C to 50°C. This makes them an ideal choice for optimizing production efficiency and ensuring production quality.



 





 



Working Principle



A water-cooled chiller utilizes a shell and tube evaporator to facilitate heat exchange between water and refrigerant. The refrigerant system absorbs the heat load from the water, causing the water to cool and generate chilled water. The heat absorbed by the refrigerant is then transported to the shell and tube condenser through the action of the compressor. Heat exchange occurs between the refrigerant and water, allowing the water to absorb the heat. Finally, the heat is dissipated to the external cooling tower through water pipes, which is known as water cooling.



 





 























































â‘ 



Compressor



⑨



Temp. sensor



â‘¡



Condenser



â‘©



Water tank



â‘¢



Dry filter



⑪



Pump pressure gauge



â‘£



Expansion valve



â‘«



Pump



⑤



Evaporator



⑬



By-pass valve



â‘¥



Ball valve



â‘­



Low pressure switch



⑦



Anti-freezing switch



â‘®



High pressure switch



⑧



Level sensor



⑯



Blower




 



Application Scope in the Industry



Chillers are widely used in various industrial productions such as plastics, electronics manufacturing, electroplating, chemical engineering, ultrasonic cooling, and printing. They are employed in the cooling of molds for plastic processing machinery, significantly improving the surface smoothness of plastic products, reducing surface flaws and internal stress, preventing shrinkage and deformation, facilitating mold release, accelerating product shaping, and thus greatly enhancing the production efficiency and product quality of plastic molding machines.



 








Injection Molding Industry







Extrusion Industry







Plastic Packaging Industry







Ultrasonic cooling







Automotive Manufacturing Industry







Chemical Engineering Industry







Electroplating Industry







Electronics Industry







Printing Industry






 




Highlights of the Product


 



Scroll Compressor



The entire range of HEMEI water cooled chillers utilizes scroll compressors. The compressor serves as the heart of the entire refrigerant cycle system. The scroll compressor adopts a dual-flex design, ensuring tight sealing between the scroll discs. This design allows the scroll discs to separate radially and axially, allowing debris or liquid to pass through without damaging the compressor. This results in increased compressor lifespan, enhanced reliability, better liquid tolerance, and improved tolerance for impurities.

 





 



Shell and Tube Evaporator



The water cooled chiller utilizes a shell and tube evaporator. In this system, the refrigerant evaporates inside the heat exchange tubes, while water flows on the shell side. To enhance the heat exchange efficiency, a 2mm thick baffle plate is installed on the shell side, causing the water to flow back and forth to create ice brine. Additionally, to maintain a stable operating temperature, the exterior shell of the evaporator is covered with insulation material. For the heat exchange tubes, we employ high-efficiency seamless copper tubes. These tubes undergo a grooving process to form internal thread fins, thereby increasing the heat exchange surface area with the refrigerant. With this technology, the heat transfer area is doubled, significantly improving the heat transfer efficiency.



 





 



Shell and Tube Condenser



Water Cooled Chiller utilizes a shell and tube condenser, with the internal copper tubes employing an outer thread embossing process. This design effectively enhances the heat exchange efficiency between the refrigerant and water during the process. Compared to traditional smooth copper tubes, the outer thread embossing process increases the surface area of the copper tubes, thereby expanding the contact area for heat exchange and improving the thermal conductivity of the condenser. This optimization design allows the condenser of the water-cooled chiller to transfer heat from the refrigerant to the water more rapidly and consistently, enabling the water to carry away the heat.

 





 




Product Specifications


 

































































































































































































































































































































HMC-XC series type



Technical parameter table of aluminum profile oxidation magnetic levitation chiller



Models



HMC-580XC



HMC-700XC



HMC-930XC



HMC-1160XC



HMC-1400XC



HMC-1630XC



HMC-1860XC



HMC-2100XC



HMC-2450XC



HMC-2800XC



Cooling

capacity



KW



582



698



932



1164



1396



1632



1864



2094



2448



2796



Kcal/h*10*



50.05



60.03



80.15



100.1



120.06



140.35



160.3



180.08



210.53



240.46



RT



165



198



265



331



397



464



530



595



696



795



Input power



KW



57



68



90



115



137



160



182



205



238



270



EER



COP



10.21



10.26



10.36



10.12



10.19



10.2



10.24



10.21



10.29



10.36



Press statting current(A)



2



2



2



2



2



2



2



2



2



2



Maximum operating current(A)



127.5



153



204



255



306



340



408



459



510



612



Maximum input power(KW)



75



90



120



150



180



200



240



270



300



360



Power supply type



3PH-380V-50Hz



Evaporator



Type



Falling film, fullliquid shell and tube heat exchanger



Refrigerant flow(m³/h)



250



300



400



500



599



700



800



899



1051



1200



Water pressure drop(Kpa)



65



79



70



75



80



80



78



76



75



78



Take over size(DN)



200



250



250



300



300



350



350



350



400



400



Condenser



Type



Horizontal shell and tube heat exchanger



Cooling water flow(m³/h)



109.605



131.389



175.3



219.383



262.95



307.376



350.943



394.34



460.72



525.901



Water pressure drop(Kpa)



52



53



55



91



98



89



95



94



81



90



Take over size(DN)



150



150



200



200



200



250



250



250



250



250



Takeover method



Flange connection



Unit size



L



3550



3600



3800



4700



4700



4800



4820



4820



4820



6080



W



1650



1650



1850



2100



1800



2100



2760



2860



2990



3140



H



2000



2000



2100



2150



2150



2120



2200



2250



2300



2350



R134a Refrigerant charge(Kg)



220



220



300



400



400



500



600



600



680



840



Unit weight(Kg)



4100



4500



5800



6500



7000



8200



8500



9500



12000



12500



Shipping weight(Kg)



4300



4700



6000



6700



7200



8400



8700



9700



12300



12800



Running weight(Kg)



4800



5200



6500



7300



7800



9000



9200



10000



13000



13500




 

































































































































































































































































































































HMC-LS series type



Technical parameter table of water-cooled magnetic levitation centrifugal chiller



Models



HMC-150LS



HMC-210LS



HMC-300LS



HMC-400LS



HMC-600LS



HMC-650LS



HMC-800LS



HMC-1000LS



HMC-1200LS



HMC-1500LS



Cooling

capacity



KW



528



740



1150



1407



2110



2286



2814



3517



4220



5276



Kcal/h*10*



45.4



63.64



98.9



121



181.46



196.59



242



302.46



362.92



453.73



RT



150



210



300



400



600



650



800



100



1200



1500



Input power



KW



89



113.3



179.1



216.8



308.9



330.8



411.4



499.6



615.2



781.6



EER



COP



5.93



6.53



6.42



6.49



6.83



6.91



6.84



7.04



6.86



6.75



Press statting current(A)



2



2



2



2



2



2



2



2



2



2



Maximum operating current(A)



180



225



368



454



704



720



920



1180



1440



1740



Maximum input power(KW)



110



141



225



278



431



441



563



722



881



1065



Power supply type



3PH-380V-50Hz



Evaporator



Type



Falling film, fullliquid shell and tube heat exchanger



Refrigerant flow(m³/h)



91



127



198



242



363



393



484



605



726



907



Water pressure drop(Kpa)



94



25



92



99



84



97



72



75



76



78



Take over size(DN)



150



150



200



200



250



250



350



350



350



400



Condenser



Type



Horizontal shell and tube heat exchanger



Cooling water flow(m³/h)



114



159



247



303



454



491



605



756



907



1134



Water pressure drop(Kpa)



71



23



70



99



64



73



81



85



89



85



Take over size(DN)



150



150



200



200



250



250



350



350



350



400



Takeover method



Clamp type



Unit size



L



2495



2795



4385



4985



4780



4780



3900



4300



5100



3700



W



1170



1190



1170



1190



2220



2220



3200



3200



3200



3400



H



2100



2200



2100



2200



2100



2100



2550



2550



2550



2550



R134a Refrigerant charge(Kg)



200



240



400



480



800



800



900



1100



1700



2000



Unit weight(Kg)



2200



2350



3740



4100



7320



7350



10300



12550



15350



18350



Shipping weight(Kg)



2250



2400



3790



4150



7400



7430



10450



12700



1550



18500



Running weight(Kg)



2550



2700



4340



4700



8520



8550



13800



16050



19350



22350




 




Product actual shooting


 



















 





 




Product Details


 







01 Microcomputer Controller

The water cooled chiller features an industry-leading LCD display microcomputer controller. This controller provides simultaneous display of the chiller's outlet temperature and the set temperature for precise temperature control. The user-friendly interface allows for easy operation and adjustment. With this controller, the water temperature can be precisely controlled within a range of 3°C to 50°C, ensuring optimal cooling performance.








02 Drying Filter System

The water cooled chiller is equipped with Emerson filters, which effectively remove impurities from the refrigerant and absorb free moisture in fluorocarbons. This system prevents the formation of ice blockages, particularly in narrow sections of pipelines (especially the valve ports of thermal expansion valves). It ensures the purity of the refrigerant and protects the compressor from potential damage.








03 High and Low Pressure Protection System

The high and low pressure protection system is designed to enhance the safety and efficiency of water pump operations. It involves the installation of high and low pressure gauges as well as a pump pressure gauge to continuously monitor the pressure of the water pump during operation.








04 Water Pumps

For chiller models ranging from 1 to 6HP, Orank stainless steel pump heads are used. For models with 8HP or higher, Taiwan Yuanli pipeline pumps are employed. These water pumps are known for their low noise operation, leak-free performance, and maintenance-free characteristics. They ensure reliable and efficient water circulation within the chiller system.








05 Electrical Self-control System

The electrical self-control system consists of power supply and automatic control components. It utilizes Siemens electronic components to ensure stable operation of the equipment. It incorporates a comprehensive range of safety protection devices, including current overload protection, high and low-pressure protection systems, and electronic time delay. These safety features provide robust protection and are complemented by an intuitive display system that alerts users to any abnormalities.






 




Application Range


 



The chiller is used in the plastic processing machinery mold cooling, electroplating industry,machinery industry, building industry, vacuum coating and food industry, etc.



 





 




About Us


 





 




Company Profile


 



SUZHOU HEMEI REFRIGERATION EQUIPMENT CO.,LTD is an enterprise mainly engaged in the production, design, research and development, operation of "Hemei" brand chiller,cooling tower, heat pump unit and other refrigeration equipment processing and manufacturing, refrigeration system design, manufacturing, installation, maintenance and debugging and technical services.



 



Relying on more than 150 professional and technical personnel from various professional research and development departments, Hemei Research Institute and enterprise postdoctoral workstation, the company independently researches and develops new products with international advanced levels of cold and hot, ecological, energy saving and environmental protection. Products are widely used in petroleum, chemical industry, plastic machinery, vacuum coating machine, injection molding machine, electroplating equipment, concave and convex plate printing machine, plasma spraying, micro arc oxidation production line, metallurgy, pharmaceutical, chemical fertilizer, food refrigeration, agricultural products deep processing, aquatic product processing, beer, dairy, commercial air conditioning, industrial refrigeration, medical air conditioning and other fields.



 





 




Company Certificate


 





 




Exhibition


 





 




Partner


 







 



 



 









 

http://www.industrychillers.com/